| Photo | Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | UserConfiguration | Type | NumberofPositions | Voltage-Input | Power(Watts) | Voltage-Isolation | Efficiency | Features | OperatingTemperature | Size/Dimension | Height | ApprovalAgency | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|   | XLC-00CONFIG POWER CHASSIS 600W 4 SLOT | 2366 | 249.83 | Add To CartInquiry Now |   Datasheet | Bulk | Xgen, XL | Active | - | Standard | 4 | 85 ~ 264 VAC | 600 W | 3 kV | 89% | - | -20°C ~ 70°C | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX4-D4CONFIGURABLE POWER SUPPLY | 2935 | 264.95 | Add To CartInquiry Now |   Datasheet | Box | UltiMod, UX | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX4C04CONFIGURABLE POWER SUPPLY | 3578 | 275.40 | Add To CartInquiry Now |   Datasheet | Box | UltiMod, UX | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XMCC01CONFIGURABLE POWER SUPPLY | 3086 | 301.71 | Add To CartInquiry Now | Box | Xgen, XM | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | |
|   | UX6R00CONFIGURABLE POWER SUPPLY | 2696 | 325.92 | Add To CartInquiry Now |   Datasheet | Box | UltiMod, UX | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XCB-00CONFIG POWER CHASSIS 700W 6 SLOT | 2220 | 327.62 | Add To CartInquiry Now |   Datasheet | Bulk | Xgen, XC | Active | - | Standard | 6 | 85 ~ 264 VAC | 700 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX6-06CONFIGURABLE POWER SUPPLY | 3011 | 329.87 | Add To CartInquiry Now |   Datasheet | Box | UltiMod, UX | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XVB-01CONFIG POWER CHASSIS 700W 6 SLOT | 2395 | 393.24 | Add To CartInquiry Now |   Datasheet | Box | Xgen, XV | Active | - | Medical | 6 | 85 ~ 264 VAC | 700 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XVE-00CONFIG POWER CHASSIS | 2944 | 525.55 | Add To CartInquiry Now | Box | Xgen, XV | Active | - | Medical | 6 | 85 ~ 264 VAC | 1340 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.55 L x 5.00 W (268.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | |
|   | XLB-00CONFIG POWER CHASSIS 400W 4 SLOT | 3533 | 243.49 | Add To CartInquiry Now |   Datasheet | Bulk | Xgen, XL | Active | - | Standard | 4 | 85 ~ 264 VAC | 400 W | 3 kV | 89% | - | -20°C ~ 70°C | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX4-04CONFIGURABLE POWER SUPPLY | 2835 | 257.40 | Add To CartInquiry Now |   Datasheet | Box | UltiMod, UX | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX4-02CONFIGURABLE POWER SUPPLY | 3574 | 260.64 | Add To CartInquiry Now |   Datasheet | Box | UltiMod, UX | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XLCC0CONFIGURABLE POWER SUPPLY | 3367 | 267.84 | Add To CartInquiry Now |   Datasheet | Box | Xgen, XL | Active | - | Standard | 4 | 85 ~ 264 VAC | 600 W | 3 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX4-D2CONFIGURABLE POWER SUPPLY | 2113 | 268.19 | Add To CartInquiry Now |   Datasheet | Box | UltiMod, UX | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX4-06CONFIG POWER CHASSIS | 2461 | 268.21 | Add To CartInquiry Now | Box | UltiMod, UX | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE | |
|   | XMB-03CONFIGURABLE POWER SUPPLY | 3969 | 292.39 | Add To CartInquiry Now |   Datasheet | Box | Xgen, XM | Active | - | Medical | 4 | 85 ~ 264 VAC | 400 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XMC-02CONFIGURABLE POWER SUPPLY | 2462 | 294.51 | Add To CartInquiry Now |   Datasheet | Box | Xgen, XM | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XLD-D1CONFIGURABLE POWER SUPPLY | 2072 | 305.65 | Add To CartInquiry Now |   Datasheet | Box | Xgen, XL | Active | - | Standard | 4 | 85 ~ 264 VAC | 750 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.55 L x 3.50 W (268.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX6-D0CONFIGURABLE POWER SUPPLY | 2404 | 319.06 | Add To CartInquiry Now |   Datasheet | Box | UltiMod, UX | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX6-04CONFIG POWER CHASSIS | 2632 | 319.06 | Add To CartInquiry Now | Box | UltiMod, UX | Active | - | Medical | 6 | 85 ~ 264 VAC | 1200 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -40°C ~ 70°C (With Derating) | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE | 
Tel